Brand Name : Sanwu
Model Number : LV Power Cable
Certification : ISO CCC
Place of Origin : Henan
MOQ : 1000M
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 200 tons per day
Delivery Time : 1-15days
Packaging Details : standard exported wooden drum or reels
Place of Original : Henan, China
Rated Voltage : 0.6/1kV
Insulated : XLPE PE LDPE PVC
Type : Low voltage
Packing : Treated wooden drum
Application : Power distribution
Description
Ceramification transforms insulation into heat-resistant barrier
Intumescent compounds expand to seal circuit pathways during fire
Neutral pH smoke prevents corrosive damage to sensitive equipment
Post-fire functionality enables faster infrastructure recovery
As fundamental components in electrical grids, LV cables balance performance with safety through precision engineering. Their application extends to renewable energy integrations, automation controls, and temporary event power. Superior designs offer easy termination, electromagnetic compatibility, and vibration resistance – ensuring operational continuity where reliability is non-negotiable.
Specification of Triplex Low Voltage Power Cable
Cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire
Conductor
Phase Conductor | Bare Neutral Messenger |
AAC | AAC |
ACSR | |
Alloy |
Service Drop Cable Meets or Exceeds the Following Specifications
1). Aluminum Wire,1350-H19 for Electrical Purposes;
2). Aluminum Conductors,Concentric-Lay-Stranded;
3). Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR);
4). Concentric-Lay-Stranded 6201-T81 Conductors;
5). Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474;
Cable's Characteristics
1). Max.admissible long time operating to conductor:
PVC or PE insulated should not exceed 70℃,XLPE insulated should not exceed 90℃;
2). Installing temperature should not be below -20℃;
3). Admissible bending radius:
When overall-diameter(D)is less than 25mm,it should be not less than 4D;
When overall-diameter(D) is 25mm or more,it should be not less than 6D;
Triplex Service Drop
Code name | AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight | Allowable Ampacities(A) | ||||
ACSR | Rated Strength lbs. | AAC | Insul.Thick.Mm | ||||||
No.&Dia.Mm | No.& Dia.Mm | No. & Dia.Mm | kg/km | XLPE | PE | ||||
Paludina | 2*6AWG+1*6AWG | 1*1.68 | 6*1.68 | 1190 | 1*4.11 | 1.14 | 166 | 85 | 70 |
Voluta | 2*6AWG+1*6AWG | 1*1.68 | 6*1.68 | 1190 | 7*1.56 | 1.14 | 170 | 85 | 70 |
Whelk | 2*4AWG+1*4AWG | 1*2.12 | 6*2.12 | 1860 | 1*5.19 | 1.14 | 251 | 115 | 90 |
Periwinkle | 2*4AWG+1*4AWG | 1*2.12 | 6*2.12 | 1860 | 7*1.96 | 1.14 | 255 | 115 | 90 |
Conch | 2*2AWG+1*2AWG | 1*2.67 | 6*2.67 | 2850 | 7*2.47 | 1.14 | 389 | 150 | 120 |
Neritina | 2*1/0AWG+1*1/0AWG | 1*3.37 | 6*3.37 | 4380 | 7*3.12 | 1.52 | 624 | 205 | 160 |
Cenia | 2*1/0AWG+1*1/0AWG | 1*3.37 | 6*3.37 | 4380 | 19*1.89 | 1.52 | 625 | 205 | 160 |
Duplex Service Drop
Code word | AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight | Allowable Ampacities(A) | |||
ALLOY | Rated Strength libs. | A AC | Insul.Thick.Mm | |||||
Number & Dia.Mm | Number&Dia.Mm | kg/km | XLPE | PE | ||||
Chihuahua | 1*6AWG+1*30.58 | 7*1.68 | 1110 | 1*4.11 | 1.14 | 98 | 85 | 70 |
Vizsla | 1*6AWG+1*30.58 | 7*1.68 | 1110 | 7*1.56 | 1.14 | 100 | 85 | 70 |
Harrier | 1*4AWG+1*48.69 | 7*2.12 | 1760 | 1*5.19 | 1.14 | 149 | 115 | 90 |
Whippet | 1*4AWG+1*48.69 | 7*2.12 | 1760 | 7*1.96 | 1.14 | 151 | 115 | 90 |
Schnauzer | 1*2AWG+1*77.47 | 7*2.67 | 2800 | 7*2.47 | 1.14 | 231 | 150 | 120 |
Heeler | 1*1/0AWG+1*123.3 | 7*3.37 | 4460 | 19*1.89 | 1.52 | 372 | 205 | 160 |
Producing Process
Applications
Emergency voice evacuation systems in high-rise buildings
Critical server room backup power circuits
Hospital life-support equipment power redundancy
Tunnel lighting and ventilation control circuits
Packing & Shipping
Packaging Details
Wooden package optional:
Size: 0.5*0.5*0.5m
0.6*0.6*0.6m; 0.7*0.7*0.7m
1.1*1.1*0.8m; 2.2*2.2*1.8m
Or suitable meters according to your needs.
Delivery Time
Generally it is 5-10 days if the goods are in stock,or it is 15.
Why Choose Us
Compliant with global fire safety standards (IEC/BS).
Safeguard lives—order fire-performance certified cables today.
About Us
Safeguard lives—order fire-performance certified cables today!
![]() |